New 2022 H19-371_V1.0 Dumps for Huawei HCSA Certified Exam Questions & Answer [Q316-Q336]

Rate this post

New 2022 H19-371_V1.0 Dumps for Huawei HCSA Certified Exam Questions and Answer

Realistic Verified H19-371_V1.0 exam dumps Q&As – H19-371_V1.0 Free Update

QUESTION 316
FusionModule1000A V2R3 version custom spray can meet UL120min fire resistance requirements

 
 

QUESTION 317
The minimum delivery time for Fusionpower is ( ) days.

QUESTION 318
Huawei Technologies Co., Ltd. is GB50174-2008 standard () is GB50174-2017 standard /

 
 
 
 

QUESTION 319
Huawei micro-modules can seal cold aisles and hot aisles ()

 
 

QUESTION 320
The parallel signal line of UPS000-A is not connected in a ring, so there is a single point of failure, which reduces the reliability of the system.

 
 

QUESTION 321
The UPS5000-E power chess block adopts the fan fault-tolerant design. When one of the fans is damaged, what percentage of the load can the power module still carry? ( )

 
 
 
 

QUESTION 322
The standard communication methods of UPS5000-E are ( )

 
 
 
 

QUESTION 323
The temperature and humidity sensors of the temperature cloud map are arranged in three layers, with the first three and the last three ( ).

 
 

QUESTION 324
Huawei network management NetEco supports northbound SNMP protocol ( )

 
 

QUESTION 325
The UPS supports a variety of systems to meet customer application grid scenarios. Which systems does the UPS2000-G 15/20KVA model support? ( )

 
 
 
 

QUESTION 326
In FusionModule2000, how to adapt the skylight when the column occupies the closed passage space in the scene around the column?

 
 
 
 

QUESTION 327
Which of the following certifications has the PDU8000 precision power distribution cabinet passed: (multiple choice)

 
 
 

QUESTION 328
The communication between the NetEco management system and the ECC800 collector adopts Huawei’s proprietary protocol BIN protocol. ( ).

 
 

QUESTION 329
UPS2000-G – The card monitors the entire parallel system, and the parallel system only needs one communication option card to monitor the entire parallel system.

 
 

QUESTION 330
For the UPS5000-A system, which of the following battery configurations is unreasonable: () (multiple choice)

 
 
 
 

QUESTION 331
PDU8000 precision power distribution cabinet supports monitoring of branch circuit phase current, active power, electric energy and branch circuit switch status.

 
 

QUESTION 332
Neteco supports centralized management of multiple data centers ( )

 
 

QUESTION 333
In a project, the customer wants to show the operation and maintenance of the data center to the external visiting customers. At this time, can the () function of the NetEco management system be used to achieve this?

 
 
 
 

QUESTION 334
FusionModule2000 does not support the configuration of sliding doors/electric doors in a single-row cabinet scenario

 
 

QUESTION 335
The new room-level air-cooled series is a full frequency conversion structure ( )

 
 

QUESTION 336
The use of IGBT rectifier high-frequency machine, compared with SCR rectifier power frequency machine, can significantly reduce the harmonics of the input current and improve the input power factor.

 
 